P92 P9220436070H

P92 P9220436070H

P92 P9220436070H接線模塊,FOXBORO產(chǎn)品外觀P92 P9220436070H嵌入式PROFIBUS不支持DOIO功能此時(shí)的接口。DOIO函數(shù)塊不返回使用嵌入式PROFIBUS作為目標(biāo)執(zhí)行時(shí)出錯(cuò)。獲取設(shè)備狀態(tài)COMMREQ獲取設(shè)備狀態(tài)COMMREQ用于獲取詳細(xì)狀態(tài)關(guān)于PROFIBUS網(wǎng)絡(luò)上特定設(shè)備的信息。在里面為了獲得最新的數(shù)據(jù),在初始版本,使其成為活動網(wǎng)絡(luò)命令。在第一個(gè)發(fā)布時(shí),...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

P92 P9220436070H

    P92 P9220436070H接線模塊,FOXBORO產(chǎn)品外觀P92 P9220436070H

    嵌入式PROFIBUS不支持DOIO功能此時(shí)的接口。DOIO函數(shù)塊不返回使用嵌入式PROFIBUS作為目標(biāo)執(zhí)行時(shí)出錯(cuò)。獲取設(shè)備狀態(tài)COMMREQ獲取設(shè)備狀態(tài)COMMREQ用于獲取詳細(xì)狀態(tài)關(guān)于PROFIBUS網(wǎng)絡(luò)上特定設(shè)備的信息。在里面為了獲得最新的數(shù)據(jù),在初始版本,使其成為活動網(wǎng)絡(luò)命令。在第一個(gè)發(fā)布時(shí),此信息返回給基于應(yīng)用程序的用戶在緩沖數(shù)據(jù)上。在首次發(fā)布后,該數(shù)據(jù)將被激活從網(wǎng)絡(luò)請求。

    P92 P9220436070H -1.jpg

    P92 P9220436070H接線模塊如果用戶應(yīng)用程序使用Get設(shè)備狀態(tài)COMMREQ通常有可能影響網(wǎng)絡(luò)性能。總配置大小PLC CPU內(nèi)的各種內(nèi)存資源約束從設(shè)備的數(shù)量和類型以及它們可以提供的數(shù)據(jù)量與主人交流??捎糜诘膬?nèi)存量PROFIBUS配置受網(wǎng)絡(luò)配置中的從屬模塊。CPU366提供最多8K字節(jié)(物理內(nèi)存)的資源數(shù)據(jù)這是由每個(gè)從模塊的GSD文件定義的,可以有所不同取決于模塊的類型。PROFIBUS Data調(diào)整可在CPU 366上配置的數(shù)據(jù)量PROFIBUS網(wǎng)絡(luò)提供高達(dá)2048字節(jié)的輸入和2048字節(jié)輸出。CPU366從停止運(yùn)行模式,wordPID參數(shù)的偏移28阻塞將被清除。SP、PV和“PREV\u FILT\u DERIV\u TERM”無意中在word處重疊PID參數(shù)塊的偏移28,導(dǎo)致在從停止切換到運(yùn)行。通過消除參數(shù)重疊,問題得到了解決。參數(shù)PREV\u FILT\u DERIV\u TERM現(xiàn)在處理為字偏移量30。

    DOIO functionality is not supported to the embedded PROFIBUS 

    interface at this time. The DOIO function block does not return an 

    error if it is executed using the embedded PROFIBUS as a target. 

    Get Device Status COMMREQ The Get Device Status COMMREQ is used to get detailed status 

    information about a particular device on the PROFIBUS network. In 

    order to get the most up to date data, a change was made after the 

    initial release to make this an active network command. In the first 

    release, this information was returned to the user application based 

    on buffered data. After the initial release, this data is actively 

    requested from the network. If the user application uses the Get 

    Device Status COMMREQ often, there is a potential to impact 

    network performance. 

    Total Configuration Size The various memory resources within the PLC CPU constrain the 

    number and type of slave devices and the amount of data they can 

    exchange with the master. The amount of memory available for the 

    PROFIBUS configuration is affected by the number and type of 

    slave modules in the network configuration. 

    The CPU366 provides up to 8K bytes (physical memory) of resource 

    data. This is defined by each slave module’s GSD file, and can vary 

    depending on the types of modules. 

    PROFIBUS Data Sizes The amount of data that can be configured on the CPU 366 

    PROFIBUS network provides up to 2048 bytes input and 2048 

    bytes output.CPU366 was switched from 

    STOP to RUN mode, word 

    offset 28 of the PID parameter 

    block would be cleared. 

    Two parameters ‘Upper Range for SP,PV’ and 

    ‘PREV_FILT_DERIV_TERM’ inadvertently overlapped at word 

    offset 28 of the PID parameter block causing it to be cleared when 

    switched from STOP to RUN. 

    The problem has been fixed by removing the overlap of parameters. 

    The parameter PREV_FILT_DERIV_TERM is now addressed to 

    word offset 30.