嘗試通過(guò)以下方式將程序員連接到RX7i以太網(wǎng)將不成功。正常連接重試對(duì)話框不會(huì)顯示。重新啟動(dòng)運(yùn)行程序員的計(jì)算機(jī)將解決該行為。在一個(gè)系統(tǒng)中,如果硬件配置是從一個(gè)目標(biāo)存儲(chǔ)的,則不要使用多個(gè)目標(biāo)目標(biāo)和邏輯從另一個(gè)目標(biāo)存儲(chǔ),通過(guò)閃存通電不起作用。觀察到的行為是flash,機(jī)器版軟件報(bào)告硬件配置和邏輯“不平等”。下載具有非常大的硬件配置或如果使用大量用戶內(nèi)存,則可能會(huì)遇到將配置寫入閃存時(shí)出現(xiàn)“序列存儲(chǔ)失敗”錯(cuò)誤。要解決此錯(cuò)誤,可以執(zhí)行以下任一操作或兩個(gè)操作:有幫助:
BENTLY 125388-01H速度監(jiān)測(cè)器1、在執(zhí)行寫入之前,執(zhí)行明確的清除閃存。
2、增加機(jī)器版軟件使用的操作超時(shí)在執(zhí)行寫入之前。這是通過(guò)擴(kuò)展目標(biāo)檢查器窗口中的其他配置控制器,并調(diào)整請(qǐng)求超時(shí)。超時(shí)可能會(huì)需要增加到60000毫秒,具體取決于使用的內(nèi)存量和閃存的狀況在一些斷電事件后,霍納熱電偶模塊(HE697THM160)可能無(wú)法成功通電。失敗后,%AI數(shù)據(jù)將無(wú)法正確更新,并將繼續(xù)返回零值。此事件沒(méi)有模塊故障指示燈。用戶應(yīng)該再次通電以恢復(fù)正常功能。擴(kuò)展機(jī)架中模塊上的故障觸點(diǎn)當(dāng)擴(kuò)展機(jī)架通電時(shí),插槽故障觸點(diǎn)將過(guò)早地表明擴(kuò)展機(jī)架中的模塊沒(méi)有在完成通電之前出現(xiàn)故障。使用輸入/輸出點(diǎn)故障觸點(diǎn)驗(yàn)證輸入/輸出的有效性。如果90-70系列遠(yuǎn)程輸入/輸出站和其中一個(gè)存在多個(gè)故障,則遠(yuǎn)程輸入/輸出站上的故障觸點(diǎn)故障觸點(diǎn)使用遠(yuǎn)程輸入/輸出站的模塊參考將錯(cuò)誤地指示遠(yuǎn)程輸入/輸出站。
BIT\u SEQ function block DIR參數(shù)BIT\u SEQ function block應(yīng)要求用戶流動(dòng)布爾值邏輯轉(zhuǎn)換為DIR參數(shù),但目前沒(méi)有。如果沒(méi)有DIR參數(shù)如果存在,則默認(rèn)情況下,BIT_SEQ將遞增。
WinLoader可能會(huì)停止在運(yùn)行Windows 2000并使用某些版本的Symantec防病毒保護(hù),如果在advanced中使用,WinLoader將失敗模式恢復(fù)需要循環(huán)計(jì)算機(jī)電源。
Infrequently, an attempt to connect a programmer to an RX7i via
Ethernet will be unsuccessful. The normal connection retry dialog will not
be displayed. Rebooting the computer that is running the programmer
will resolve the behavior.
Don’t use multiple targets In a system in which the hardware configuration is stored from one
target and logic is stored from a different target, powering-up from flash
will not work. The observed behavior is that, following a power up from
flash, Machine Edition software reports hardware configuration and logic
"not equal".
Sequence store failure When downloading projects with very large hardware configuration or
which use large amounts of user memory, it is possible to encounter a
“Sequence Store Failure” error when writing the configuration to flash.
To work around this error, either or both of the following actions may be
helpful:
1. Perform an explicit clear of flash prior to performing the write.
2. Increase the operation timeout used by Machine Edition software
prior to performing the write. This is done by expanding the
Additional Configuration in the Inspector window for the target
controller, and adjusting the Request Timeout. The timeout may
need to be increased to as much as 60000 msec, depending on
the amount of memory used and the condition of the flash memoryfter some power loss events, the Horner Thermocouple module
(HE697THM160) may fail to power up successfully. After failure, the %AI
data will not be updated correctly and will continue to return zero values.
There are no module fault indicators for this event. The user should
power cycle again to restore normal function.
Fault contacts on modules in expansion rack When an expansion rack powers up, the slot fault contacts will
prematurely indicate that the modules in the expansion rack are not
faulted before they complete their power up. Use I/O point fault contacts
to verify validity of the I/O.
Fault contacts on Remote I/O Station If multiple faults exist in a Series 90-70 Remote I/O Station and one of
them is corrected, a FAULT contact that uses the Remote I/O Station’s
module reference will incorrectly indicate that no faults exist at the
Remote I/O Station.
BIT_SEQ function block DIR parameter The BIT_SEQ Function Block should require the user to flow BOOLEAN
logic into the DIR parameter, but currently does not. If no DIR parameter
is present, the BIT_SEQ will increment by default.
WinLoader may stop operating On computers running Windows 2000 and using some versions of
Symantec Antivirus protection, WinLoader will fail if used in advanced
mode. Recovery requires cycling the computer's power.