TRICONEX 9853-610

TRICONEX 9853-610

TRICONEX 9853-610卡件說明書控制器使用EGD數(shù)據(jù)錯誤的UDP校驗和客戶報告PLC正在使用UDP錯誤的EGD數(shù)據(jù)校驗和。在以前的版本中,當(dāng)加速度模式設(shè)置為ON(默認(rèn))時,未驗證UDP校驗和以減少過載。以太網(wǎng)固件6.20實現(xiàn)了一種方法,允許在以下情況下計算校驗和:加速模式設(shè)置為ON,不會影響性能??刂破髟谝韵虑闆r下沒有響應(yīng):配置了TOS/QOS客戶報告,當(dāng)配置TOS/QOS位時,控制器...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

TRICONEX 9853-610

    TRICONEX 9853-610卡件說明書

    控制器使用EGD數(shù)據(jù)錯誤的UDP校驗和客戶報告PLC正在使用UDP錯誤的EGD數(shù)據(jù)校驗和。在以前的版本中,當(dāng)加速度模式設(shè)置為ON(默認(rèn))時,未驗證UDP校驗和以減少過載。以太網(wǎng)固件6.20實現(xiàn)了一種方法,允許在以下情況下計算校驗和:加速模式設(shè)置為ON,不會影響性能。

    控制器在以下情況下沒有響應(yīng):配置了TOS/QOS客戶報告,當(dāng)配置TOS/QOS位時,控制器

    沒有響應(yīng)。

    9853-610.jpg

    TRICONEX 9853-610卡件說明書固件已更正以繼續(xù)當(dāng)其他設(shè)備使用TOS/QOS位時。響應(yīng)幀將設(shè)置TOS/QOS位為0。

    SRTP通信問題當(dāng)多個連接快速打開和關(guān)閉時,以太網(wǎng)接口可能進(jìn)入阻止遠(yuǎn)程客戶端使用連接的狀態(tài)SRTP通信。這已在以太網(wǎng)固件中得到糾正版本6.20。

    以太網(wǎng)限制和開放問題主題描述車站經(jīng)理“PARM”命令幫助文本錯誤

    雖然“parm v”Station Manager命令工作正常,“v”聯(lián)機(jī)幫助不支持顯示子系統(tǒng)代碼(SRTP服務(wù)器)。統(tǒng)計的SRTP請求數(shù)可能會有所不同當(dāng)運行多個SRTP客戶端通道時,報告的請求數(shù)由客戶端和服務(wù)器決定,連接之間可能有所不同。SRTP連接在IP地址已更改以太網(wǎng)接口不會在之前終止所有打開的SRTP連接更改其IP地址。一旦本地IP地址發(fā)生更改,任何現(xiàn)有的打開的TCP連接無法正常終止。這會留下SRTP連接打開,直到其底層TCP連接超時。如果更快需要恢復(fù)SRTP連接,請修改“wkal_idle”高級用于將TCP保持活動計時器降低到所需最大值的用戶參數(shù)保持?jǐn)嚅_連接的時間。參見TCP/IP以太網(wǎng)PACSystems通信,GFK-2224,了解詳細(xì)信息。

    Controller consumed EGD data with

    bad UDP checksum

    Customer reported that the PLC is consuming EGD data with bad UDP

    checksum. In previous releases, while acceleration mode is set to ON (default),

    the UDP checksum was not validated to reduce the overload. Ethernet firmware

    6.20 implements a method that allows checksums to be calculated when

    acceleration mode is set to ON without impacting performance.

    Controller did not respond when

    TOS/QOS were configured

    Customers reported that when TOS/QOS bits are configured, then the Controller

    does not respond. The firmware has been corrected to continue to communicate

    when TOS/QOS bits are used by other devices. The response frame will set the

    TOS/QOS bit to 0.

    SRTP communication issue When multiple connections were opened and closed very quickly, the Ethernet

    interface could enter a state that prevented remote clients from connecting using

    SRTP communications. This has been corrected in Ethernet firmware

    version 6.20.

    Ethernet Restrictions and Open Issues

    Subject Description

    Station Manager “PARM” command

    help text is wrong

    Although the “parm v” Station Manager command works correctly, the “v”

    subsystem code (SRTP server) is not shown as supported by the online help.

    Number of SRTP requests tallied

    may vary

    When running multiple SRTP client channels, the number of requests, as reported

    by the client and the server, may differ between the connections.SRTP connections remain open after

    IP address changed

    The Ethernet Interface does not terminate all open SRTP connections before

    changing its IP address. Once the local IP address has changed, any existing

    open TCP connections are unable to normally terminate. This can leave SRTP

    connections open until their underlying TCP connections time out. If quicker

    recovery of the SRTP connection is needed, modify the “wkal_idle” Advanced

    User Parameter to reduce the TCP keep alive timer down to the desired maximum

    time for holding open the broken connection. Refer to TCP/IP Ethernet

    Communications for PACSystems, GFK-2224, for details.