ICS TRIPLEX T8830

ICS TRIPLEX T8830

主營產(chǎn)品PLC可編程控制器模塊,DCS卡件,ESD系統(tǒng)卡件,振動監(jiān)測系統(tǒng)卡件,汽輪機控制系統(tǒng)模塊,燃氣發(fā)電機備件等,優(yōu)勢品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、P...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

ICS TRIPLEX T8830

    主營產(chǎn)品

    PLC可編程控制器模塊,DCS卡件,ESD系統(tǒng)卡件,振動監(jiān)測系統(tǒng)卡件,汽輪機控制系統(tǒng)模塊,燃氣發(fā)電機備件等,優(yōu)勢品牌:Allen Bradley、BentlyNevada、ABB、Emerson Ovation、Honeywell DCS、Rockwell ICS Triplex、FOXBORO、Schneider PLC、GE Fanuc、Motorola、HIMA、TRICONEX、Prosoft等各種進口工業(yè)零部件

    產(chǎn)品廣泛應(yīng)用于冶金、石油天然氣、玻璃制造業(yè)、鋁業(yè)、石油化工、煤礦、造紙印刷、紡織印染、機械、電子制造、汽車制造、塑膠機械、電力、水利、水處理/環(huán)保、鍋爐供暖、能源、輸配電等等

    ICS TRIPLEX T8830控制模塊

    重合閘嘗試的最大故障持續(xù)時間“t操作”

    如果故障持續(xù)一段時間,則成功重合閘的概率降低。電力系統(tǒng)的可能性故障持續(xù)很長時間后,如果自動重合閘嘗試失敗,則變得不穩(wěn)定的可能性更大時期正是由于這些原因,在開始可啟動重合閘的故障是有限的。過錯使用參數(shù)“t Oper”設(shè)置持續(xù)時間。故障持續(xù)時間的計時器由拾取信號啟動從保護功能(啟動)。導致跳閘的故障在“t Oper”被鎖定(“Def.Trip”)后,重合閘不會發(fā)生

    如果故障持續(xù)時間在保護跳閘之前到期,自動重合閘被阻止,回收時間開始。示例:距離函數(shù)的時間“T操作”<“延遲(2)”表示自動重合閘僅在第一距離內(nèi)發(fā)生故障區(qū)域(“延遲(1)”。

    僅使用電流的方案不需要此功能功能。二進制輸入“啟動”和“跳閘斷路器3P”連接在一起(見第3.5.32.3節(jié))?;厥諘r間“不抑制”禁止時間的目的之一是允許:斷路器恢復其全部耐壓能力。為此結(jié)束,在設(shè)定的時間內(nèi)禁用自動重合閘功能

    以下事件之一后的參數(shù)“禁止”:

    最后一次重合閘嘗試

    故障后保護跳閘導致的最終跳閘持續(xù)時間“t操作”

    鑒別時間和死區(qū)時間之間的重復跳閘(正在演變的故障,請參閱O/P信號“Def.Trip”)。

    關(guān)閉信號持續(xù)時間“不關(guān)閉”斷路器閉合信號(命令O/P“閉合CB”)的最大持續(xù)時間由參數(shù)“t閉合”確定。在此期間發(fā)生的任何跳閘信號都會覆蓋關(guān)閉信號。第二次、第三次或第四次重合閘嘗試只能如果下一次行程發(fā)生在“關(guān)閉”時間內(nèi),則發(fā)生。

    辨別時間“t 1P discrim”和“t 3P discrim”識別時間決定以下情況下的程序:死區(qū)時間內(nèi)發(fā)生的不同類型的故障(演變故障),即其他兩個相位中的一個也拾取或跳閘信號復位并再次拾取。辨別時間是

    從死時間開始。如果在識別時間到期和死區(qū)時間結(jié)束之前,由于不斷演變的故障而再次出現(xiàn)跳閘信號,則回收計時器并啟動最終跳閘(“Def.trip”)。死期并且信號“AR in prog.”重置。

    如果第一個故障最初是接地故障,并在時間“t死1 1P”,但在鑒別時間“t”結(jié)束之前

    Discrim 1P'啟動死區(qū)時間“t Dead1 3P”,并進行三相重合閘。

    Maximum fault duration for a reclosure attempt ‘t Oper’

    If a fault has persisted for some time, the probability of a successful reclosure reduces. The likelihood of the power system

    becoming unstable is also greater for an unsuccessful auto-reclosure attempt following a fault which has persisted for a long

    period. It is for these reasons that the time after the inception of

    a fault during which reclosure can be initiated is limited. The fault

    duration is set using parameter ‘t Oper’.

    The timer for the fault duration is started by the pick-up signal

    from the protection function (Start). Faults resulting in tripping

    after ‘t Oper’ are locked out (‘Def. Trip’) and reclosure does not

    take place.

    Should the fault duration time expire before the protection trips,

    auto-reclosure is blocked and the reclaim time is started.Example:

    Time ‘T Oper’ < ‘Delay(2)’ of the distance function means that

    auto-reclosure only takes place for faults in the first distance

    zone (‘Delay(1)’).

    This function is not required for schemes that only use current

    functions. The binary inputs ‘Start’ and ‘Trip CB 3P’ are connected together (see Section 3.5.32.3.).

    Reclaim time ‘t inhibit’

    The purpose of the inhibit time is among other things to permit

    the circuit-breaker to recover its full voltage withstand. To this

    end, it disables the auto-reclosure function for the time set for

    parameter ‘t inhibit’ after one of the following events:

     the last reclosing attempt

     a definitive trip resulting from a protection trip after the fault

    duration time ‘t Oper’

     a recurring trip between discrimination time and dead time

    (evolving fault, see O/P signal ‘Def. Trip’).

    Close signal duration ‘t Close’

    The maximum duration of the circuit-breaker close signal (command O/P ‘Close CB’) is determined by the parameter ‘t Close’.

    Any tripping signal which occurs during this time overrides the

    close signal. A second, third or fourth reclosure attempt can only

    take place, if the next trip occurs within the time ‘t Close’.

    Discrimination times ‘t 1P discrim.’ and ‘t 3P discrim.’

    The discrimination time determines the procedure in the event of

    a different kind of fault occurring during the dead time (evolving

    fault), i.e. one of the other two phases also picks up or the tripping signal resets and picks up again. The discrimination time is

    started together with the dead time. Should a tripping signal recur due to an evolving fault between the expiry of the discrimination time and before the end of the dead time, the reclaim timer

    is started and a definitive trip (‘Def. Trip’) initiated. The dead time

    is also discontinued and the signal ‘AR in prog.’ reset.

    If the first fault was initially an earth fault and evolves during the

    time ‘t Dead1 1P’, but before the end of the discrimination time ‘t

    Discrim 1P’, the dead time ‘t Dead1 3P’ is started and threephase reclosure takes place.

    品牌:ICS TRIPLEX

    型號:T8830

    產(chǎn)地:美國

    質(zhì)保:365天

    成色:全新/二手

    發(fā)貨方式:快遞發(fā)貨


圖片名 客服

在線客服 客服一號