MOOG D136-002-005伺服控制器手動(dòng)模式激活當(dāng)DECS-100在手動(dòng)模式下運(yùn)行時(shí),該LED點(diǎn)亮。手動(dòng)模式通過(guò)以下方式啟用:BESTCOMS軟件。低頻有源當(dāng)發(fā)電機(jī)頻率降低到低于欠頻設(shè)定點(diǎn)時(shí),該LED亮起DECS-100在選定的伏特/赫茲曲線(xiàn)上進(jìn)行調(diào)節(jié)。通信端口通信端口位于后面板上,并且包括一個(gè)RS-232(DECS-B-9)母接頭。這個(gè)通信端口用作編程接口DECS-100的(設(shè)置)。圖2...

  • 功能特性
  • 參數(shù)規(guī)格
  • 視頻
  • 應(yīng)用案例
  • 下載

D136-002-005

    微信圖片_20220907175947.jpg

    MOOG D136-002-005伺服控制器

    手動(dòng)模式激活

    當(dāng)DECS-100在手動(dòng)模式下運(yùn)行時(shí),該LED點(diǎn)亮。手動(dòng)模式通過(guò)以下方式啟用:BESTCOMS軟件。

    低頻有源當(dāng)發(fā)電機(jī)頻率降低到低于欠頻設(shè)定點(diǎn)時(shí),該LED亮起DECS-100在選定的伏特/赫茲曲線(xiàn)上進(jìn)行調(diào)節(jié)。通信端口

    通信端口位于后面板上,并且包括一個(gè)RS-232(DECS-B-9)母接頭。這個(gè)通信端口用作編程接口

    DECS-100的(設(shè)置)。圖2-2說(shuō)明了通信端口。

    編程需要標(biāo)準(zhǔn)的九針串行連接在DECS-100和使用BESTCOMS軟件運(yùn)行的IBM兼容PC。

    BESTCOMS軟件是基于Microsoft Windows?的隨附的通信軟件包DECS-100。提供了最佳通信的詳細(xì)說(shuō)明

    第5節(jié),BESTCOMS軟件。本節(jié)描述了DECS-100的功能,并解釋了其操作特點(diǎn)。緩和理解,DECS-100功能如圖3-1的框圖所示在DECS-100功能標(biāo)題下的段落中提供了每個(gè)功能塊的說(shuō)明阻礙。

    DECS-100的操作功能包括四種操作模式、四種保護(hù)功能、啟動(dòng)規(guī)定,無(wú)功下垂補(bǔ)償、低頻補(bǔ)償和可選電壓匹配。詳細(xì)的DECS-100標(biāo)題下的段落中提供了每個(gè)操作特征的說(shuō)明操作特性。

    以下段落描述了圖3-1所示的每個(gè)功能塊

    每個(gè)模塊連同所有功能模塊輸入和輸出的操作一起進(jìn)行說(shuō)明。

    模擬輸入電路七個(gè)模擬電壓和電流可被感測(cè)并施加到DECS-100。母線(xiàn)電壓

    在包含電壓的裝置上的端子B3和B1處監(jiān)控C相和A相母線(xiàn)電壓匹配。在這些端子處可感測(cè)到高達(dá)600 Vac的標(biāo)稱(chēng)電壓。在此監(jiān)測(cè)的電壓輸入在被應(yīng)用到模數(shù)轉(zhuǎn)換器(ADC)的輸入之前被縮放和調(diào)節(jié)。施加到ADC的總線(xiàn)電壓信號(hào)用于計(jì)算跨接總線(xiàn)電壓的rms值相C和A(總線(xiàn)VC-A)。

    發(fā)電機(jī)電壓在端子E1(A相)、E2(B相)和E3(C相)處監(jiān)測(cè)發(fā)電機(jī)電壓。名義上的在這些端子處可感測(cè)到高達(dá)600 Vac的電壓。施加到這些輸入的電壓在被施加到ADC的輸入之前被縮放和調(diào)節(jié)。

    Manual Mode Active

    This LED lights when the DECS-100 is operating in Manual mode. Manual mode is enabled through

    BESTCOMS software.

    Underfrequency Active

    This LED lights when the generator frequency decreases below the underfrequency setpoint and the

    DECS-100 is regulating on the selected volts per hertz curve.

    COMMUNICATION PORT

    The communication port is located on the rear panel and

    consists of a female, RS-232 (DECS-B-9) connector. The

    communication port serves as an interface for programming

    (setup) of the DECS-100. Figure 2-2 illustrates the location of

    the communication port.

    Programming requires a standard, nine-pin, serial

    communication cable connected between the DECS-100 and

    an IBM-compatible PC operating with BESTCOMS software.

    BESTCOMS software is a Microsoft Windows?-based

    communication software package that is supplied with the

    DECS-100. A detailed description of BESTCOMS is provided

    in Section 5, BESTCOMS Software. This section describes how the DECS-100 functions and explains its operating features. To ease

    understanding, DECS-100 functions are illustrated in the block diagram of Figure 3-1. A detailed

    description of each function block is provided in the paragraphs under the heading of DECS-100 Function

    Blocks.

    DECS-100 operating features include four operating modes, four protective functions, startup provisions,

    reactive droop compensation, underfrequency compensation, and optional voltage matching. A detailed

    description of each operating feature is provided in the paragraphs under the heading of DECS-100

    Operating Features. The following paragraphs describe each of the function blocks illustrated in Figure 3-1. The function of

    each block is explained along with the operation of all function block inputs and outputs.

    Analog Input Circuits

    Seven analog voltages and current may be sensed and applied to the DECS-100.

    Bus Voltage

    C-phase and A-phase bus voltages are monitored at terminals B3 and B1 on units that include voltage

    matching. Nominal voltages of up to 600 Vac may be sensed at these terminals. Voltage monitored at this

    input is scaled and conditioned before being applied to the input of the analog-to-digital converter (ADC).

    This bus voltage signal applied to the ADC is used to calculate the rms value of the bus voltage across

    phases C and A (Bus VC-A).

    Generator Voltage

    Generator voltage is monitored at terminals E1 (A-phase), E2 (B-phase), and E3 (C-phase). Nominal

    voltages of up to 600 Vac may be sensed at these terminals. Voltage applied to these inputs is scaled and conditioned before being applied to the input of the ADC. 

    品牌:MOOG