WOODWARD 9907-186工控模塊備件
將功能接地螺釘擰緊
至1.47 N?m(13 lb?in)的扭矩。5.向計(jì)算機(jī)提供18…32V直流電源。重要事項(xiàng)使用功能接地螺釘時(shí),請(qǐng)使用1.5 mm2(16 AWG)或更大的外部導(dǎo)線將計(jì)算機(jī)連接到接地。使用當(dāng)?shù)貦z查機(jī)構(gòu)允許的絕緣顏色的接地線-V+V顯示計(jì)算機(jī)顯示的環(huán)形連接器功能接地螺釘22用于危險(xiǎn)場(chǎng)所的工業(yè)計(jì)算機(jī)自動(dòng)化出版物6181X-IN001D-EN-P-2015年7月連接到網(wǎng)絡(luò)計(jì)算機(jī)具有兩個(gè)1 GB LAN端口。計(jì)算機(jī)通過(guò)使用帶RJ45連接器的CAT5或CAT5E雙絞線以太網(wǎng)電纜連接到以太網(wǎng)。附件和替換零件您可以在以下自動(dòng)化網(wǎng)站查看附件和替換部件列表:在安裝新組件之前,請(qǐng)檢查其規(guī)格,以驗(yàn)證其是否與計(jì)算機(jī)兼容。記錄新部件的型號(hào)和序列號(hào)以及任何其他相關(guān)信息,以供將來(lái)參考。
警告:
連接LAN電纜時(shí),請(qǐng)確認(rèn)電纜已完全插入LAN端口,且閂鎖已接合。如果不這樣做,可能會(huì)導(dǎo)致電弧,從而在危險(xiǎn)位置引發(fā)爆炸。重要提示:為了防止以太網(wǎng)通信性能下降,請(qǐng)勿使計(jì)算機(jī)或電纜受到極端輻射或傳導(dǎo)高頻噪聲。在工業(yè)環(huán)境中,以太網(wǎng)通信需要正確的電纜布線和電源調(diào)節(jié)。自動(dòng)化公司建議您將所有以太網(wǎng)電纜通過(guò)專用金屬導(dǎo)管布線。為了提高性能可靠性,在電纜端部安裝鐵氧體磁珠過(guò)濾器。重要提示:我們建議您僅使用Allen-Bradley批準(zhǔn)的配件和替換零件。顯示計(jì)算機(jī)非顯示計(jì)算機(jī)危險(xiǎn)場(chǎng)所工業(yè)計(jì)算機(jī)23自動(dòng)化出版物6181X-IN001D-EN-P-2015年7月電壓注意事項(xiàng)計(jì)算機(jī)包含線路電壓。
Tighten the function grounding screw
Torque to 1.47 N ? m (13 lb ? in). 5. Provide 18... 32V DC power supply to the computer. IMPORTANT When using a functional grounding screw, use an external wire 1.5 mm2 (16 AWG) or larger to connect the computer to ground. Use the grounding wire of insulation color allowed by the local inspection authority - V+V shows the ring connector function displayed by the computer Grounding screw 22 Industrial computer automation publication 6181X-IN001D-EN-P-2015 July connected to the network computer has two 1 GB LAN ports. The computer is connected to the Ethernet network by using CAT5 or CAT5E twisted pair Ethernet cables with RJ45 connectors. Accessories and replacement parts You can view a list of accessories and replacement parts on the following automation website: Before installing a new component, check its specifications to verify that it is compatible with your computer. Record the model and serial number of the new part and any other relevant information for future reference.
Warning:
When connecting the LAN cable, make sure that the cable is fully plugged into the LAN port and that the latch is engaged. Failure to do so could result in an electric arc that could cause an explosion in a hazardous location. Important: To prevent the Ethernet communication performance from declining, do not expose the computer or cable to extreme radiation or conducted high-frequency noise. In an industrial environment, Ethernet communication requires proper cable routing and power conditioning. The automation company recommends that you route all Ethernet cables through special metal conduits. In order to improve the performance reliability, a ferrite bead filter is installed at the end of the cable. Important: We recommend that you use only Allen Bradley approved accessories and replacement parts. Display computer Non display computer Industrial computer in hazardous areas 23 Automation publication 6181X-IN001D-EN-P-2015 July Voltage precautions Computer includes line voltage.