MVME5100-0163處理器卡件
((WinVista/7/8)OPC服務器7-16 DriveWindow 2如果您從未(或很少)需要連接到ACS800系列驅動器,我們建議您建議DriveDA在文件DriveDA的[Servers]部分設置Count=1,以完全不連接到DriveOPC。ini:[Servers]并行=1計數(shù)=1[Servers.0]名稱=ABB。DriveDA ParallelChannels=1[Servers.1]名稱=ABB。SMP文件位于:?Documents and Settings\All Users\Application Data\DriveWare(WinXP)或?Program Data\DriveWare(WinVista/7/8)另請參閱:連接到OPC服務器7。配置DDCS/UDP DriveWindow 2.40(實際上包含DriveOPC 2.10)支持新的DDCS/UDP協(xié)議,該協(xié)議允許DDCS光纖網(wǎng)絡通過以太網(wǎng)連接到PC。它需要支持該協(xié)議的設備,如NETA-21。OPC服務器DriveWindow 2 7-17 7.1.1啟用NETA-21 DDCS網(wǎng)關NETA-21的出廠設置已禁用NETA-21中的DDCS網(wǎng)關。要能夠使用DDCS/UDP,必須啟用網(wǎng)關。為此,您可以使用web瀏覽器連接到NETA-21 IP地址。您需要知道用戶名和密碼才能登錄。然后導航到設置->設備界面,選擇DDCS選項卡并單擊設置。將顯示界面設置對話框。選擇Enable from Ethernet GW,單擊Save,最后注銷。7.1.2配置DDCS/UDP DDCS/UDP配置信息保存在dwc_NETA中。ini文件,位于:?Documents and Settings\All Users\Application Data\DriveWare(WinXP)或?Program Data\DriveWare(WinVista/7/8)DDCS/UDP配置對話框實際上實現(xiàn)了一個特殊的ini文件編輯器。OPC服務器7-18 DriveWindow 2配置通過從網(wǎng)絡菜單的配置子菜單中選擇DDCS/UDP來完成。請注意,如果您連接到OPC服務器,DDCS/UDP命令將變灰。配置只能在OPC服務器斷開時進行。將打開DDCS/UDP配置對話框,您可以選擇要使用的配置。OPC服務器DriveWindow 2 7-19 7.1.3配置您可以有幾種現(xiàn)成的配置(例如,針對不同的站點),但當您連接到DriveOPC時,只有一種配置在使用中。除了默認配置之外,您可以添加、重命名和刪除自己的配置??梢跃庉嬎信渲貌⑵鋸椭频叫屡渲谩D梢詮摹熬庉嫛辈藛位蛴益I單擊“當前配置”下拉列表時顯示的上下文菜單中選擇操作?;蜃⒁猓部梢酝ㄟ^點擊Del鍵來刪除所選的當前配置。配置可以包含以下連接到DDCS/UDP設備的方法的任意組合:?固定IP列表(不在默認配置中)。?附近的設備,即本地以太網(wǎng)段中的所有設備(通過廣播搜索)。?Intranet設備,即與PC位于同一子網(wǎng)中的所有設備(通過廣播搜索)。?由IP地址和子網(wǎng)掩碼標識的遠程子網(wǎng)列表(不在默認配置中)。實際上,固定IP是具有子網(wǎng)掩碼255.255.255.255的遠程子網(wǎng)的一種特殊情況。但是,您可以為其指定固定的信道號,這在其他方法中是不可能的。在實踐中,您只使用只有固定IP的配置。使用廣播的方法可以用于具有DDCS/UDP設備的訓練或其他條件,其IP地址頻繁改變。OPC Server 7-20 DriveWindow 2 7.1.4測試配置要測試選定的當前配置,請單擊測試按鈕。如果按鈕呈灰色,則表示您有舊版本的DriveOPC
WinVista/7/8) OPC Server 7-16 DriveWindow 2 If you never (or seldom) need to connect to an ACS800 family of drive, we recommend that you advice DriveDA not to connect to DriveOPC at all by setting Count=1 in the [Servers] section of the file DriveDA.ini: [Servers] Parallel=1 Count=1 [Servers.0] Name=ABB.DriveDA ParallelChannels=1 [Servers.1] Name=ABB.SMP The file is located in: ? Documents and Settings\All Users\Application Data\DriveWare (WinXP), or ? Program Data\DriveWare (WinVista/7/8) See Also: Connecting to OPC Server 7. Configuring DDCS/UDP DriveWindow 2.40 (actually DriveOPC 2.10 included in it) supports a new DDCS/UDP protocol, which allows the DDCS fibre optic network to be connected to the PC over Ethernet network. It requires a device supporting the protocol, such as NETA-21. OPC Server DriveWindow 2 7-17 7.1.1 Enabling NETA-21 DDCS Gateway Factory settings of NETA-21 have the DDCS gateway disabled in NETA-21. To be able to use DDCS/UDP, the gateway has to be enabled. To do that you use a web browser to connect to the NETA-21 IP address. You need to know a user name and password to get logged in. Then navigate to Settings -> Device interfaces, select DDCS tab and click Settings. Interface settings dialog box is displayed. Select Enable from Ethernet GW, click Save and finally log out. 7.1.2 Configuring DDCS/UDP DDCS/UDP configuration information is kept in dwc_NETA.ini file, which resides in: ? Documents and Settings\All Users\Application Data\DriveWare (WinXP), or ? Program Data\DriveWare (WinVista/7/8) The DDCS/UDP Configuration dialog boxes actually implement a special INI-file editor. OPC Server 7-18 DriveWindow 2 Configuring is done by selecting DDCS/UDP from the Configuration submenu of the Network menu. Note that the DDCS/UDP command is grayed if you are connected to an OPC Server. Configuring can only be done while OPC Server is disconneced. The DDCS/UDP Configuration dialog box is opened and you can choose the configuration to work with. OPC Server DriveWindow 2 7-19 7.1.3 Configurations You can have several readymade configurations (for different sites, for example), but only one of them is in use when you connect to DriveOPC. With the exception of the Default configuration, you can add, rename, and delete configurations of your own. All configurations can be edited and copied to a new. You can select to operation either from the Edit menu or the context menu, which is shown when you right click Current configuration drop down list. or Note that you can delete the selected Current configuration also by hitting the Del key. A configuration can contain any combination of the following methods of connecting to DDCS/UDP devices: ? A list of fixed IPs (not in the Default configuration). ? Devices near, i.e., all devices in the local Ethernet segment (searched by broadcast). ? Intranet devices, i.e., all devices in the same subnet as the PC (searched by broadcast). ? A list of remote subnets identified by an IP address and subnet mask (not in the Default configuration). Actually a fixed IP is a special case of remote subnet having the subnet mask 255.255.255.255. However, you can specify a fixed channel number for it, which is not possible in other methods. In practise you use only configurations that have just fixed IPs. The methods using broadcast could be used in training or other conditions having DDCS/UDP devices, IP addresses of which change frequently. OPC Server 7-20 DriveWindow 2 7.1.4 Testing a Configuration To test the selected Current configuration, click the Test button. If the button is grayed, you either have an old version of DriveOPC