FOXBORO FBM201 P0914SQ電阻輸入分壓器編程
當(dāng)這些字段中的任何一個(gè)被寫入(通過(guò)單個(gè)32位寫入或單獨(dú)的16位寫入)時(shí),無(wú)論定時(shí)器是啟用還是禁用,相應(yīng)的定時(shí)器都會(huì)在定時(shí)器時(shí)鐘的下一個(gè)上升沿加載寫入值。存儲(chǔ)在該寄存器中的值也會(huì)在計(jì)時(shí)器的終端計(jì)數(shù)(或超時(shí))時(shí)自動(dòng)重新加載。計(jì)時(shí)器3加載計(jì)數(shù)寄存器(TMRLCR3)計(jì)時(shí)器3為32位寬,并從計(jì)時(shí)器3加載計(jì)數(shù)器寄存器(TMLCR3)獲得其加載計(jì)數(shù),該寄存器位于BAR2中地址的偏移0x14處。此寄存器中的位映射如下:寫入此字段時(shí),無(wú)論計(jì)時(shí)器是啟用還是禁用,計(jì)時(shí)器3都會(huì)在計(jì)時(shí)器時(shí)鐘的下一個(gè)上升沿加載寫入值。存儲(chǔ)在該寄存器中的值也會(huì)在計(jì)時(shí)器的終端計(jì)數(shù)(或超時(shí))時(shí)自動(dòng)重新加載。計(jì)時(shí)器4加載計(jì)數(shù)寄存器(TMRLCR4)計(jì)時(shí)器4為32位寬,并從位于BAR2中地址偏移0x18處的計(jì)時(shí)器4加載計(jì)數(shù)器寄存器(TMLCR4)中獲取其加載計(jì)數(shù)。此寄存器中的位映射如下:寫入此字段時(shí),無(wú)論計(jì)時(shí)器是啟用還是禁用,計(jì)時(shí)器4都會(huì)在計(jì)時(shí)器時(shí)鐘的下一個(gè)上升沿加載寫入值。存儲(chǔ)在該寄存器中的值也會(huì)在計(jì)時(shí)器的終端計(jì)數(shù)(或超時(shí))時(shí)自動(dòng)重新加載。
When either of these fields are written (either by a single 32-bit write or separate
16-bit writes), the respective timer is loaded with the written value on the next rising
edge of the timer clock, regardless of whether the timer is enabled or disabled. The
value stored in this register is also automatically reloaded on terminal count (or
timeout) of the timer.
Timer 3 Load Count Register (TMRLCR3)
Timer 3 is 32-bits wide and obtains its load count from the Timer 3 Load Count
Register (TMRLCR3), located at offset 0x14 from the address in BAR2. The mapping
of bits in this register are as follows:When this field is written, Timer 3 is loaded with the written value on the next rising
edge of the timer clock, regardless of whether the timer is enabled or disabled. The
value stored in this register is also automatically reloaded on terminal count (or
timeout) of the timer.Timer 4 Load Count Register (TMRLCR4)
Timer 4 is 32-bits wide and obtains its load count from the Timer 4 Load Count
Register (TMRLCR4), located at offset 0x18 from the address in BAR2. The mapping
of bits in this register are as follows:
When this field is written, Timer 4 is loaded with the written value on the next rising
edge of the timer clock, regardless of whether the timer is enabled or disabled. The
value stored in this register is also automatically reloaded on terminal count (or
timeout) of the timer.